Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-7 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	25
Date	08/07/14
Start Time	15:46:14
Diameter Midpoint
 11.3	186925
 11.8	292845
 12.2	287717
 12.6	312455
 13.1	337196
 13.6	363261
 14.1	388147
 14.6	416377
 15.1	450292
 15.7	480049
 16.3	518141
 16.8	549209
 17.5	578105
 18.1	617336
 18.8	653254
 19.5	687567
 20.2	719441
 20.9	752377
 21.7	784594
 22.5	815309
 23.3	846194
 24.1	871581
 25.0	896268
 25.9	921395
 26.9	935123
 27.9	931629
 28.9	943050
 30.0	926156
 31.1	913769
 32.2	896084
 33.4	857671
 34.6	816935
 35.9	756004
 37.2	709665
 38.5	635192
 40.0	570629
 41.4	497538
 42.9	429836
 44.5	361747
 46.1	299645
 47.8	244485
 49.6	194710
 51.4	150759
 53.3	115855
 55.2	87519.5
 57.3	65154.6
 59.4	47157.5
 61.5	33780.3
 63.8	23905.9
 66.1	16956.3
 68.5	11659.7
 71.0	8112.22
 73.7	5644.46
 76.4	4183.33
 79.1	3338.85
 82.0	2922.37
 85.1	2630.78
 88.2	2443.01
 91.4	2241.1
 94.7	1949.21
 98.2	1570.75
101.8	1234.56
105.5	1016.83
109.4	887.678
113.4	660.576
117.6	537.341
121.9	395.826
126.3	330.089
131.0	312.022
135.8	271.427
140.7	205.934
145.9	177.155
151.2	170.231
156.8	138.375
162.5	100.754
168.5	96.4523
174.7	85.5905
181.1	63.6947
187.7	60.6302
194.6	50.1329
201.7	61.364
209.1	51.1377
216.7	58.3942
224.7	50.813
232.9	73.0659
241.4	38.7727
250.3	53.5651
259.5	44.2405
269.0	57.22
278.8	44.4535
289.0	29.8592
299.6	35.4666
310.6	32.7247
322.0	25.2315
333.8	34.564
346.0	22.1098
358.7	35.7593
371.8	22.6088
385.4	15.3821
399.5	18.4316
414.2	17.044
429.4	9.80125
445.1	11.4869
461.4	10.9215
478.3	11.1402
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.7054
High Voltage	9925.07
Lower Size(nm)	11.1397
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1084.4
Median(nm)	25.8073
Mean(nm)	27.1146
Geo. Mean(nm)	25.285
Mode(nm)	28.9026
Geo. Std. Dev.	1.45625
Total Concentration(#/cm)	2.62413e+007
Comment	